Operation and Calibration of DSC apparatus

 
1.0    PURPOSE: 

1.1    To lay down the procedure for operation and calibration of  Mettler Toledo DSC Apparatus.

2.0    SCOPE.

2.1    This SOP is applicable for operation and calibration of Mettler Toledo DS

0 reactions

Procedure For Security And Access Control

1.0    PURPOSE:

1.1    To lay down the procedure for security and access control of chromatographic software.

2.0    SCOPE:

2.1    This SOP is applicable for quality control department.

3.0    RESPONSIBILITY:

3

0 reactions

Operation of Gas Chromatograph

1.0              PURPOSE:

1.1To lay down the procedure for operation of gas chromatograph (SHIMADZU GC-2010 with AOC-5000) system.

2.0              SCOPE:

2.1&nb

0 reactions

Operation of Liquid Chromatograph (SHIMADZU LC2010)

1.0    PURPOSE:

1.1    To lay down the procedure for Analytical Reference Numbering System.

2.0    SCOPE:

2.1    This procedure is applicable for Quality control department.

3.0    RESPONSIBILITY:

3.1 &nbs

0 reactions

Calibration of PH Meter

1.0    PURPOSE: 

            1.1     To lay down the procedure for Calibration of pH Meter. 

2.0    SCOPE

2.1    This procedure is applicable for Calibration of pH meters located in the Quality co

0 reactions

Calibration of Gas Chromatograph

1.0    PURPOSE:

1.1    To lay down the procedure for Calibration of Gas chromatograph.

2.0    SCOPE:

2.1    This procedure is applicable for Calibration of Gas chromatograph in           Quality control departme

0 reactions

Preventive Maintenance of Stability Chambers

1.0    PURPOSE:

1.1    To lay down the procedure for Preventive maintenance of Stability chambers.

2.0    SCOPE:

2.1    This procedure is applicable to Quality Control for stability study only.

3.0    RESPONSIBILI

0 reactions

Calibration of Polarimeter

1.0        PURPOSE: 

1.1    To lay down the procedure for Calibration of polarimeter. 

2.0    SCOPE

2.1    This procedure is applicable for Calibration of all polarimeter located in    quality control lab.

3.

0 reactions

Calibration of JASCO FT IR 410 Spectrometer

1.0        PURPOSE

1.1    To lay down the procedure for Calibration of JASCO FT /IR-410 Spectrometer. 

2.0    SCOPE

2.1         This SOP is applicable for Calibration of JASCO FT / IR-410 Spectrometer in quality

0 reactions

Calibration Of Analytical Balance

1.0    PURPOSE
       
1.1    To lay down the procedure for Calibration of Analytical balance. 

2.0    SCOPE

2.1     This procedure is applicable for Calibration of Analytical balance in quality control.

0 reactions